CONTEXT

An effective solution to reopen a washed-out roadway

Recent storms caused extensive damage to Vermont State Highway Route 116 in Hinesburg, VT, washing out a significant section of the roadway. With numerous roads in the region still closed due to washouts, there was an urgent need for rapid and effective repairs to restore critical transportation routes.

The Vermont Department of Transportation approached Soleno to explore potential solutions for their specific challenges. Leveraging our expertise in custom pipe fabrication, we provided a large-diameter pipe solution, ensuring a timely and effective response to their infrastructure needs.

DOWNLOAD

SOLUTION

Culverts are essential components of stormwater management systems, enabling water to flow beneath
roadways and preventing erosion and flooding

Soleno responded promptly to the emergency request, using its stock of KUSTOMFLO pipes to  address the situation effectively. By mid-week KUSTOMFLO pipes were shipped, and the contractor installed the pipe by Friday. The road reopened shortly thereafter, significantly minimizing disruption to local transporation.

The installed product consisted of 93.5 linear feet of 94.5-inch pipe KUSTOMFLO pipe. The pipe was intentionally oversized to allow for partial burial of the invert, enabling the installation of riprap to support aquatic life passage. Soleno’s ability to meet the tight timeline, combined with it’s emergency readiness and in-stock availability, ensured that the road could be reopened within a week.

BENEFITS

A functioning culvert preserves the safety and usability of transportation routes and protects nearby ecosystems and communities.

The rapid response from Soleno demonstrated its commitment to addressing emergency situations effectively. The use of oversized KUSTOMFLO pipes provided a sustainable solutions, accommodating environmental considerations such as aquatic life passage.

The durability of the product and the efficiency of the installation process ensured a long-term, reliable outcome. The contractor was able to complete the project and move on to other critical repairs in the region, further demonstrating the effectiveness of the solution.

KUSTOMFLO pipes meet the requirements of current standards, including ASTM F894, DIN 16,961, EN 13,476, and BNQ 1809-300 for both gravity and pressure pipe applications. They provide a wide diameter selection and unique joining technologies and allow for the manufacturing of custom manholes and accessories to meet the specific needs of any project.

More about KUSTOMFLO

KUSTOMFLO HDPE pipes are known for their robust and tailor-made piping systems designed to meet specific project requirements. The ADAPTIVE design allows optimization of the pipe profile to align with precise needs of the project or applicable standards. These HDPE pipes are enginereed to customer specifications to optimize the performance of a flexible pipe. They offer versatility with hundreds of profile types and configurations with variable wall thickness, including solide wall, closed profile, and open profile options.